MCP5A MCP5A
Analogue Addressable Manual Call Points are a high-reliability fire alarm activation device. The MCP5A may be installed as either a flush or surface mounted device in a normal internal environment.

M500k M500k
An alternative model to the MCP5A, the M500K analogue addressable Manual Call Point maintains the traditional shape and test key. It may be mounted flush, or surface using the BBS-X2 backbox.

M500MB M500MB
M500MB Monitor Module is designed to interface to contact devices such as security contacts, water flow switches, manual call points etc.

M500S M500S
M500S Supervised Control Module provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as sounders,strobes,bells,etc.

M500R M500R
M500R Relay Control Module provides two sets of voltage free changeover relay contacts for interfacing with output devices where supervision of the cabling is not required, such as mechanical services, door holders etc.

M500C M500C
M500CH Control Module provides either a supervised drive circuit or an unsupervised set of changeover relay contacts. Conversion from supervised to unsupervised requires the snapping off of a small part of the module, which is not reversible.

M500X M500X
M500X Isolator Module is an automatic switch that opens when the loop voltage drops below four volts. Isolator modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop.

M500X SMB500
The SMB500 is a analogue address module surface mount box.

M210E-CZR M210E-CZR
M210E-CZR conventional Zone Monitor module allows a zone of IS conventional detectors to be connected to Pertronic Analogue Addressable Panels.

M512ME M512ME (Discontinuted)
M512ME conventional Zone Monitor module allows a zone of conventional detectors to be connected to Pertronic Analogue Addressable Panels.

M501M M501M
M501M Mini-Monitor Module is designed to interface to contact devices, such as security contacts, water flow switches, manual call points etc.

M503M M503M
M503M Micro Module provides a two wire initiating circuit for normally open contact fire alarm and supervisory devices. A circuit may be monitored for open-circuit and short-circuit faults. An LED indicator output drive is provided to allow visual monitoring of the module's operating condition.

M220E M220E
The M220E is a dual channel input module used for the monitoring of normally open contact fire alarm and supervisory devices. Valid addresses on F100A and F120A are 0 to 99.

M221E M221E
The M221E is a dual input single output module used for the monitoring of normally open contact fire alarm and supervisory devices. It also provides a single pole changeover contacts for the control of auxiliary devices such as fire shutters. Valid addresses on F100A and F120A are 0 to 99.

M200E-SMB M220E-SMB
The M220E-SMB is a analogue addressable euro module surface mount box.

M500DMR M500DMR
The M500DMR is a dual input dual output module used for the monitoring of normally open contact fire alarm and supervisory devices. It also provides two single pole changeover contacts for the control of auxiliary devices such as fire shutters.

ISO524-1 ISO524-1
The System Sensor ISO524-1 short circuit isolator is designed for use with all 200, 500 and 700 series of analogue addressable detectors and modules. They prevent an entire communications loop from being disabled when a short circuit occurs.

Isolate Timer Module ITM
Pertronic Industries' Isolate Timer Module provides a countdown timer for isolating a zone for a pre-determined period. It may be used to isolate devices in a particular zone, when work that is being performed may cause an alarm activation.

F100LR F100LR
Pertronic Industries' Loop Responders extend the F120A & F100A analogue addressable automatic fire systems by allowing conventional detectors circuits to be used on the system.

F100LRU F100LRU
Pertronic Industries' Loop Relays extend the F120 & F100 analogue addressable automatic fire alarm systems by allowing relays to be controlled and operated from an analogue loop.

F100PFCU F100PFCU
Pertronic Industries' Fan Controllers are used for smoke hazard managment in accordance with AS1668 within buildings.